ECHO-EC

red flame icon
Enhanced Acoustic Sensitivity
combination of superb sensing elements, digital signal processing algorithm with advanced filtering techniques allow device to measure wall thickness at high resolution
red flame icon
Maximum reliability
rigorous self diagnostics, data averaging and use of filtering techniques provide fail to safe reliable operation
red flame icon
Non-intrusive mounting
The Echo-EC system comes with mounting frame which is attached to the pipe to provide a secure fit while maintaining pipeline integrity.
red flame icon
Real-time data
Real-time data on wall loss reduces need for PIG inspection activities.

Electrical Specifications

Input Voltage: +24VDC (Nominal) +18 to 32 VDC
Battery Operated by Request

Power Consumption: ≤ 4W for the monitoring module
≤ 5V for the EC sensor

Output Signals: Wireless HART
Digital RS-485 Modbus RTU

Mechanical Specifications

Dimensions: Monitoring Module 5.9” x Ø 3.9” (150 mm x Ø100 mm)
ECHO EC sensor 2’’ x 4’’ x 5’’ (50 mm x 95 mm x 125 mm)

Material: Stainless Steel 316L

Weight: Monitoring Module 6 lbs (3 kg)
ECHO EC Sensor 1 lb (0.5 kg)

Functional Specifications

Method of Operation: Passive acoustic

Flow Regime: Oil, Gas, Water, Multiphase

Units of measurement: Wall loss (mm), corrosion rate (%)

Calibration: factory calibrated, no field calibration required

Resolution: 0.001” (0.025mm)

Pipe Size: > 3 inch OD (76 mm)

Coverage Area: 32 sq.ft (3 sq.m)

Wall Thickness: 3 – 50 mm (0.1 -2 inches)

Pipe Material: Metal Alloys

Pipe Coating: Any, no need to remove coating

Operating Temperature: -20C to +80C ( -76F to 185F)

Pipe Surface Temperature: -100C to +290C ( -148F to 554F)

Storage Temperature: -50C to +50C ( -58F to 122F)

Design Life: 30 years

Welds

Heated Weld Zones

Pipeline bends/elbows

Pipeline-joints

Vessels/Tanks


Visit our Customer Center for product resources

 

ECHO-EC RESOURCES

Contact Us / Find a Rep
+1.408.886.9746