ECHO-UW

red flame icon
Enhanced Acoustic Sensitivity
Superb sensing element, digital signal processing algorithm with advanced filtering techniques allow device to detect the smallest particle.
red flame icon
Maximum Reliability
Rigorous self diagnostics, data averaging and use of filtering techniques provide fail to safe reliable operation.
red flame icon
Low Maintenance Cost
Minimum maintenance on site which makes it an easy choice for operator.
red flame icon
Non-intrusive Mounting
Connect Echo by supplied clamp to pipe or for subsea installation, place it in a funnel and you are ready to go.

Electrical Specifications

Power Requirements: +24VDC Nominal (+18 to 32VDC)

Power Consumption:  ≤ 2,4 W (depends on redundancy)

Outputs From Echo: 4-20mA (SIIS level 1),

CANopen CiA 443 (SIIS Level 2),

Digital RS-485 Modbus RTU

 

Mechanical Specifications

Material: UNS S31803/2205 Duplex SS or Titanium

Dimensions: 20” x Ø 5” (500 mm x Ø 130 mm)

Weight in air: 13lbs (6 kg) Titanium / 19 lbs (10 kg) UNS S31803/2205 Duplex SS

Coating: Xylan 1070

ROV Handle type: D-Handle as standard (T-Handle, Fishtail handle, O-handle available)

Interface Connector type: Omnitec MKII, Tronic Connector, ODI Connector

Functional Specifications

Method of Operation: Passive acoustic

Flow Regime: Oil, Gas, Multiphase

Units of measurement: g/s

Calibration: factory calibrated

Uncertainty : ± 3 -10 % (depends on flow and calibration)

Flow Velocity: ~ 1 m/s

Particle Size: ≥ 10 μm – in gas; ≥ 20 μm – in oil

Depth: 4,500 m (14,760 ft)

External Pressure: 30 MPa

Operating Temperature: -20C to +80C ( -76F to 185F)

Pipe Surface Temperature: -100C to +290C ( -148F to 554F)

Storage Temperature: -50C to +50C ( -58F to 122F)

Design Life: 30 years

Subsea Manifolds

Subsea Jumpers

Subsea Xmas trees

Subsea Pipe spools


Visit our Customer Center for product resources

 

ECHO-UW RESOURCES

Contact Us / Find a Rep
+1.408.886.9746